Phone:
+86-151-5067-1075
Features:
1. Voice prompt
2. Standard built-in Recorder, Defibrillation discharge trigger recording
3.The ECG waveform via paddle electrode
4. Standard Li-ion battery
5. Heart Rate, Lead, Alarm On/Off, Delivered Energy Displayed on screen
6. 7 inches TFT colour display Optional: Spo2 / AED Standard: Biphasic defibrillation / ECG / Print / Li-ion Battery
Defibrillator | |
ECG | 3-lead ECG cable, or 5-lead ECG cable, paddles. |
Displayed on monitor, paddles, I, II, III,AVR, AVL, AVF, V. | |
NIBP | Method: automatic oscillation |
Working mode: manual/automatic | |
TEMP | Measurement range: 20-45ºC |
SpO2 | Display: SpO2 value, pulse histongram, waveform, pulse |
Pulse range | 0~300bpm Pulse accuracy: ±2bpm |
Defibrillator | Biphasic/ Manual / External Synchronous / Asynchronous Defibrillation |
Charge Time | Less than 10 seconds to 360 Joules |
Energy Selection | Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules |
Standard Adult/Pediatric Paddles | Reusable external adult paddles (pediatric paddles integrated) |
AED Optional | Adult Mode: 150J/150J/200J |
120J/120J/150J | |
Children Mode: 50J/50J/75J | |
30J/30J/50J | |
Power requirements | |
AC Power supply | 100V~240V, 50Hz/60 Hz |
Vehicle Voltage (Option) | DC 12V |
Internal Battery Backup | |
Battery type | Rechargeable Li-ion battery |
Charging time | Time-Minimum of 4 hours for full charging |
Battery charging | During AC Power Supply operation of the device |
Charging /Low Battery Indication | Red LED |
Battery Capacity | 100% of the battery will provide 120-min of monitoring; and 30 discharges at 360 joules |
Features:
1. Voice prompt
2. Standard built-in Recorder, Defibrillation discharge trigger recording
3.The ECG waveform via paddle electrode
4. Standard Li-ion battery
5. Heart Rate, Lead, Alarm On/Off, Delivered Energy Displayed on screen
6. 7 inches TFT colour display Optional: Spo2 / AED Standard: Biphasic defibrillation / ECG / Print / Li-ion Battery
Defibrillator | |
ECG | 3-lead ECG cable, or 5-lead ECG cable, paddles. |
Displayed on monitor, paddles, I, II, III,AVR, AVL, AVF, V. | |
NIBP | Method: automatic oscillation |
Working mode: manual/automatic | |
TEMP | Measurement range: 20-45ºC |
SpO2 | Display: SpO2 value, pulse histongram, waveform, pulse |
Pulse range | 0~300bpm Pulse accuracy: ±2bpm |
Defibrillator | Biphasic/ Manual / External Synchronous / Asynchronous Defibrillation |
Charge Time | Less than 10 seconds to 360 Joules |
Energy Selection | Selectable at 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 joules |
Standard Adult/Pediatric Paddles | Reusable external adult paddles (pediatric paddles integrated) |
AED Optional | Adult Mode: 150J/150J/200J |
120J/120J/150J | |
Children Mode: 50J/50J/75J | |
30J/30J/50J | |
Power requirements | |
AC Power supply | 100V~240V, 50Hz/60 Hz |
Vehicle Voltage (Option) | DC 12V |
Internal Battery Backup | |
Battery type | Rechargeable Li-ion battery |
Charging time | Time-Minimum of 4 hours for full charging |
Battery charging | During AC Power Supply operation of the device |
Charging /Low Battery Indication | Red LED |
Battery Capacity | 100% of the battery will provide 120-min of monitoring; and 30 discharges at 360 joules |